What you'll learn:
- Which kind of backflow preventer you have, and whether it's the kind that freezes
- What actually cracks when a backflow freezes
- The 15-minute routine for the freeze DFW gets most years, including the 45-degree ball valve step
- When the forecast calls for more than that, and what the trigger actually is
- The failure in the manufacturer's own manual that homeowners cause themselves
- What to wrap it with, from towels to a fitted cover and insulated rock
- Which DFW cities require the above-ground RPZ type
Experience level: Beginner (you'll need to find your shut-off and turn a couple of handles)
- Most DFW homes have a double check in an underground box. I've never seen one of those freeze
- The ones that freeze sit above ground next to the house: pressure vacuum breakers on homes, and RPZs on commercial properties and in cities that require them
- What breaks is usually the riser pipes and the ball valves, not the whole device. On a commercial unit, a split 2-inch brass ball valve gets expensive
- For the normal event: shut the water off, relieve the pressure, leave the ball valves at 45 degrees, wrap it. Fifteen minutes
- The trigger for going further is forecast hours below freezing, not a date. One 26-degree day is not February 2021
- Closing the isolation valve and leaving the line charged is its own failure mode, straight out of the Febco manual
Which Backflow Do You Have?
Every sprinkler system in Texas has a backflow preventer between the city water and your zones. It keeps lawn water from siphoning back into the drinking water. Whether yours needs freeze protection depends almost entirely on which type you have and where it sits.
Double check in an underground box. This is what most DFW homes have. It sits in a rectangular valve box in the yard, usually near the water meter or between the meter and the house. Being below ground is what protects it. I have really never seen one of these have a freeze problem. Some people stuff insulation in the box, and I don't think it's necessary unless the device is basically touching the lid, which I just don't see.
Worth being precise about why, because the usual explanation is wrong. It is not a frost line. Texas rule 30 TAC 344.62(l) asks for six inches of select backfill over buried pipe, two inches where a utility, a structure, or roots make six impractical, and DFW has no meaningful design frost depth to clear in the first place. What protects a buried device and the pipe around it is the thermal mass of the soil: the ground gives up heat slowly, and one cold night cannot pull enough heat out of it to freeze the water inside. That protection has a limit, and sustained cold with no daytime thaw is what exhausts it. Which is why the next thing to sort out is what kind of freeze you are looking at.
Pressure vacuum breaker (PVB). This one sits above ground, usually right against the house, with copper or brass risers coming up out of the dirt. It's the most common type on homes that do have an above-ground device, and it's the one that freezes.

Reduced pressure zone (RPZ). Also above ground, usually near the building. You see these mostly on commercial properties, and on homes in cities that require them. They have the same freeze problem as a PVB, with more brass to crack.
Anti-siphon valves. These are zone valves with a built-in backflow device, mounted above ground. I've only seen a few of them around DFW.

What Actually Breaks
When an above-ground backflow freezes, it's usually not the whole device that's ruined. Water trapped in the pipe expands as it turns to ice, and it splits whatever is weakest. In my experience that's:
- The risers, the copper or brass pipes coming up out of the ground into the device.
- The ball valves, the shut-off handles on each side. Water sits trapped inside the ball, and when it freezes it cracks the valve body.
On commercial properties it gets expensive. I've seen 2-inch brass ball valves split open on commercial units, and a 2-inch brass valve isn't a cheap part.
Two Freezes, Two Protocols
North Texas gets two different winter events and they do not call for the same work. Knowing which one is coming is the difference between fifteen minutes and a service call.
The one that recurs: a cold day. On January 15, 2024 the high at DFW was 26 degrees, the lowest maximum temperature ever recorded there for that date, beating 31 degrees from 1917, with a forecast low of 11. One cold day, warmer by the weekend. That event threatens the above-ground assembly, the risers under it, and the ball valves. Nothing buried. The fifteen-minute routine below is the entire job.
The one everybody remembers: sustained cold. In February 2021 DFW recorded a low of minus 2 degrees, second-coldest on record at the airport behind minus 8 in February 1899, and stayed below freezing for 139 consecutive hours. Almost six days with no thaw. There is no warm afternoon in the middle of that to save a part you missed, and it is the one case in DFW where draining the system down past the backflow earns its cost.
The trigger is not a date. It is how many consecutive hours the forecast keeps us below freezing, and how far below. A night or a day that recovers the next afternoon: do the fifteen minutes. Multiple days with no thaw and lows in the teens or lower, or an empty unheated house: go further, and drain what will drain. An annual October appointment answers neither question, because it charges for the big protocol in the years you needed the small one and it has already been forgotten by the time a February event arrives. For the rest of the system in both cases, my North Texas winterization guide has the full version.
The 15-Minute Routine Before a Freeze
When a freeze is in the forecast, do this the day before, while it's still above freezing:
- Turn off the water to the system. Close the irrigation isolation valve, the shut-off between your house water and the sprinkler system. If you're not sure where yours is, my emergency shut-off guide walks through finding it.
- Drain what you can. With the water off, open the small test cocks on the device and let the water run out. If you have a way to push a little air through the backflow itself to clear more of it, even better. This isn't a whole-system blowout, which North Texas doesn't need. It's just getting water out of the one part that sits above ground.
- Leave the ball valves at 45 degrees. Turn each ball valve handle halfway, so it's sitting at an angle instead of fully open or fully closed. A half-open ball can't trap a pocket of water inside the valve, which is exactly the water that cracks it. This isn't a field trick I made up: Watts publishes the half-open position in its own winterization instructions for the Febco 765, specifically so the ball valve bodies drain.
- Set the controller to off so it doesn't try to run a zone into a frozen pipe.
- Wrap it, down to the ground, which is the next section.
That is the whole fifteen minutes. The order matters: shut off, then relieve, then wrap. Wrapping a charged assembly just insulates the water that is going to split it.
This is the one failure homeowners cause themselves, and it is in the manufacturer's own manual. Febco's installation instructions for the 765 warn that thermal water expansion and water hammer downstream of the assembly "can cause excessive pressure increases," and that those conditions have to be eliminated to avoid damage. Picture it: you close the isolation valve, the assembly and the line behind it are still full, the sun comes out that afternoon, and the water in that sealed section warms and expands with nowhere to go. That cracks assemblies in weather that never got cold. It is a pressure failure wearing a freeze failure's clothes. Close the valve, then open the test cocks. Step 1 without step 2 is worse than doing nothing.
Be realistic about step 2. The test cocks drain the device, but not the vertical risers coming up out of the ground. Febco, which makes one of the most common pressure vacuum breakers, says in its own winterization instructions the assembly can't be adequately drained through the test cocks. Their answer is a drain valve below the device, but plumbing code doesn't allow a buried stop-and-waste drain on the drinking-water side, so you won't find one on a typical DFW install. On an RPZ with a Y-strainer ahead of it, opening the strainer would let some of that water out, but the strainers are usually buried and hard to get to. Assume the risers still have water in them. That's why the wrapping below has to go all the way down to the ground.
The double check itself won't freeze, so skip the wrapping. But I'd still shut the water off: turn off the isolation valve if you can find it, and set the double check's own ball valves to 45 degrees. The reason is what's downstream of it.
Here's a job that shows why. A homeowner left the water on to the sprinkler system over a freeze. One of the zone valves had a tiny, tiny leak, not enough to notice, and it was slowly feeding a set of copper risers in a flower bed against the house. Normally the low-head drainage would have emptied those risers after the zone shut off. With the valve weeping, they stayed full of water. When it froze, they split all the way up and down. With the water shut off, that leak would have had nothing to feed it.
How to Wrap an Above-Ground Backflow
Once it's drained, cover it. Any of these works, roughly in order from quick fix to best:
- Towels. A couple of heavy towels wrapped around the device and the risers, held in place so they don't blow off. Cover the risers all the way down to the ground, not just the brass body.
- A fitted insulated pouch. They make insulated covers shaped to slide down over a backflow. They fit better than towels and don't get soaked.
- A pouch plus an insulated rock. Put the pouch on, then set a fake insulated rock cover over the top. That combination does pretty well, and it looks better in a flower bed than a pile of towels all winter.
- Heat tape. For a device that's especially exposed, you can wrap thermal heat tape around the pipe and device under the insulation and plug it in. It needs an outdoor outlet within reach.
Freeze Relief Valves
There's also a small add-on valve made for above-ground backflows, the Zurn Wilkins ZWFR freeze relief valve. It threads onto the downstream test cock of an RPZ or a pressure vacuum breaker. When the water inside drops to about 35 degrees, it opens and starts dripping, which pulls warmer water up from underground and through the device. When the water warms back to about 40 degrees, it closes.
It works the opposite way from everything above: the water stays on, and water runs through the device all night instead of sitting still in it. A few things to know before you rely on one:
- It doesn't protect everything. Water only moves up through the inlet riser and the device to where the valve is mounted. The outlet riser heading back down to the zones has no flow, so it still needs wrapping.
- It discharges water. Zurn warns that the water it lets out has to drain somewhere it won't damage the property around it.
- It's not a substitute for winterizing. Zurn's own instructions say it "is not intended to replace the standard winterization process." It's backup for a surprise freeze, not a reason to skip the wrap.
DFW Cities That Require an RPZ
An RPZ is the above-ground type, so if your property is required to have one, freeze protection isn't optional. Texas irrigation rules require an RPZ where the system carries a health hazard, most commonly a home on a septic system, a system with chemicals injected into the water, or a system tied into a second water source like a well, pond, or rainwater tank. Beyond that, it comes down to the city:
- Mesquite requires an RPZ on commercial irrigation. Residential systems in Mesquite use a double check in a box below grade.
- Heath requires an RPZ when the property is on a septic system.
- Fate treats a septic system with irrigation as a health hazard that requires an RPZ.
- Plano requires an RPZ (or an air gap) when the system has chemical injection or quick-coupler hose connections. Plano also requires an RPZ to sit above ground, and the city recommends a freeze-proof enclosure on a concrete slab.
If you're not sure what your city requires, the city's backflow or cross-connection office can tell you. Whatever the reason you have one, an RPZ sits above ground, and it needs the same draining and wrapping as any other exposed backflow.
Get It Done Before the Freeze
If you'd rather not crawl around the side of the house in the cold, or you have a commercial RPZ with big brass valves you don't want to gamble on, book a freeze prep visit. I recommend scheduling it for January. I'll shut the system down, drain what can be drained, set the valves, and get the backflow covered, and you'll know where your shut-off is for next time. Then in March, after the last hard freeze, it gets turned back on.
For the rest of the system, my North Texas winterization guide covers the controller, exposed pipe, and spring start-up. If you just bought the place and have not found the shut-off yet, start with bought a house with a sprinkler system and taking over the sprinkler system. And once the system comes back on in spring, the thing that actually decides whether it waters well here is the soil: see clay soil irrigation and cycle and soak.
References
- Febco, Installation, Operation and Maintenance Instructions, Model 765 Pressure Vacuum Breaker (IOM-F-765). "The device must be protected from freezing." Thermal water expansion and downstream water hammer can cause excessive pressure increases.
- Watts, Winterization Instructions for Febco Model 765 (IS-F-765-Winterization). Keep the system shut-off closed through winter; after draining, leave ball valves half open so the valve bodies drain.
- Zurn Wilkins, Model ZWFR freeze relief valve installation instructions. Opens near 35°F, closes near 40°F, discharges water, and "is not intended to replace the standard winterization process."
- 30 Texas Administrative Code § 344.62(k) and (l). Isolation valve required between the meter and the backflow assembly; six inches of select backfill over buried pipe.
- 30 Texas Administrative Code § 344.50 and § 344.51(d). Device selection by hazard level; a property on an on-site sewage facility is a health hazard requiring a reduced pressure assembly.
- National Weather Service via The Dallas Morning News, January 17, 2024, and WFAA, "North Texas' most significant winter weather events in history." DFW high of 26°F on January 15, 2024; February 2021 record low of −2°F and 139 consecutive hours below freezing.
